GENERAL FEATURES
High reliability even at the maximum declared operating values. Galvanic separation between power and control circuits.
Control card one type only (interchangeable) for all model of the same series.
Protections against overvoltages, spikes, overloads and tacho failure.
Supply: line nominal voltage ± 10%, frequency 50/60 Hz ± 4%.
Feedback: selectable from tachogenerators or from motor armature.Speed control: double current-speed feedback loopRatio: 1 ÷ 100 typical with tacho - 1 ÷ 30 typical with armature feedback and Rxl compensation.
Stability (with tacho feedback): up to <0.1% of max speed at the following conditions: 0 to 100%, load ± 10%, line voltage ± 4%, line frequency ± 10°C ambient temperature. Analog inputs 10V, 1mA max; Digital input n.c. for control safety disable. Analog output 10V, 10mA max: for cascade operation.
scr regulators

Adjustment of (by means of trimmers)
  • Torque (0 - 100%)
  • Max speed
  • Acceleration ramp up and down
  • Dynamic gain
Max operating temperature: 0 ÷ 55°C (models without fan) with 1.25% derating per °C above 35°C.
Air humidity: 90% max without condensation.
 
Accessories
  • Electrical and electronic gears
  • Rotary cross and flying cut controllers
  • Single-multi axes positioning controls
  • Torque-limiters for D.C./A.C. motors
  • Multidrivers control board
  • Motorized potentiometers
  • Digital potentiometers with memory
  • Refrence signals opto isolators

Microvar

scr regulators

Minivar N

scr regulators

Bikini

scr regulators

 
MICROVAR
MINIVAR N
BIKINI
Unidirectional Tipo 0,3 0,5 1 1,5 2 10U 13U 10R 13R     5R 10R 15R
Bidirectional                   5RR 10RR 5RR 10RR 15RR
Motor power HP
KW
0,3 0,5 1 1,5 3 2 2,6 2 3,3 2,6 4,3 1 2 1 2 3
0,22 0,37 0,74 1,1 2,2 1,5 1,9 1,5 2,5 1,9 3,2 0,74 1,5 0,74 1,5 2,2
Supply voltage V~ 230 230 230 230 230
400
Armature voltage V 170 170 170 170 170
290
Nominal armature current A 1,5 2,5 5 7,5 15 10 13 10 13 5 10 5 10 15
Peak armature current A 2,5 4 7,5 11 22 15 17 15 17 7,5 15 7,5 15 22
Max field voltage V 200 200 200 200 200
340
Field current A 1 1,5 1,5 2,5
Supply line single-phase single-phase single-phase
Bridge type semicontrollato half controlled fully controlled fully controlled
Auxiliary ventilation no no no
Dimensions
Weight
L 170 170 210 155 197 77
H 95 95 95 140 140 210
P 40 50 55 160 160 164
kg 0,3 0,3 0,4 1,2 1,5 1,8



scr regulators
 
Unidirectional Tipo 11R 13R 16R 24R 32R
Bidirectional 11RR 13RR 16RR 24RR 32RR
Motor power HP
KW
2,2
3,6
2,6
4,3
3,2
5,3
4,6
8
6,4
10,6
1,6 2,7 1,9 3,2 2,3 3,9 3,5 5,8 4,7 7,8
Supply voltage V~ 230
400
Armature voltage V 180
290
Nominal armature current A 11 13 16 24 32
Peak armature current A 16 21 26 32 40
Max field voltage V 200
340
Field current A 2,5
Supply line single-phase
Bridge type half controlled
Auxiliary ventilation no si
Dimensions
Weight
L 320
H 185
P 160
kg 2,2



scr regulators
 
Unidirectional Tipo 20R 30R 40R 50R 60R 80R 100R 160R 200R
Bidirectional 20RR 30RR 40RR 50RR 60RR 80RR 100RR 160RR 200RR
Motor power HP
KW
10 15 20,4 26,5 31 42 53 85 108
7,4 11 15 19,5 23 31 39 62,5 80
Supply voltage V~ 400
Armature voltage V 440/400
Nominal armature current A 20 30 40 50 60 80 100 160 200
Peak armature current A 26 39 52 65 78 104 130 208 260
Max field voltage V 340
Field current
A 8 12
Supply line three-phase
Bridge type fully controlled
Auxiliary ventilation no si
Dimensions
Weight
L 340 340 480
480 480
H 250 250 250
P 171 233 233
kg 5,8 8 8 8 12
8,6 9,4 10 10 14


Back




     