Story | Products | Plants Division | Sistems and Automation | Planning and Software | Download Area | Place | Photovoltaic
Contact us

Inverters

MODEL E2-2P2 E2-2P5 E2-201 Inverter E2
Applicable Motor Output (KW) 0.2 0.4 0.75
Rated Horsepower(HP) 1/4 1/2 1
Rated current 1.4 2.3 4.2
Rated capacity 0.53 0.88 1.6
Weight 0.76 0.77 0.8
Input max voltage Signal phase 200~240V (+10%, -15%, 50/60 Hz (+/-5%))
Output max voltage Three phases 200~240V
Input signal state PNP type (Source) input
Control Method Sinusoidal wave PWM control

Frequency
Control
Frequency Control Range 1~120 Hz
Frequency Setting Resolution Digital: 0.01 Hz (0~99.9Hz): 1 Hz (100~120Hz)
Analog 0.06Hz/60Hz
Keypad Setting Method Direct use key for setting
Frequency Setting Signal 0~10V, 0~20mA
Frequency limit Frequency upper / lower limit
Control
Characteristics
Carry frequency 1~8 kHz
Accel / Decel Time 0.1~999 Seconds
V/F pattern 6 patterns
Torque Control Torque level adjustable (Manual torque boost)
Multifunction inputs 2 input contacts of the following signals available to select: Speed 1 command, Jog operation, Emergency stop, External Base block, Reset command
Multifunction outputs 1 NO output contact of the following signals available to select: During fault, running output, agreed frequency
Approx. Braking torque 20% (Braking resistor cannot be mounted)
Built-in Function Deceleration or Free run to stop, Auto reset, DC injection frequency/time/level constant select
Digital operator monitor 3-digit 7 segment display frequency/function constants/fault history/CPU version
Ambient temperature -10~40°C
Humidity 0~95% RH non-condensing
Vibration Under 0.5 G
EMC Specifications Class A (Filter built-in Unifiltered)
Enclosure IP20
UL UL 508
Protective
Functions
Overload 150% per 1 min.
Over-voltage DC bus exceeds 410V
Under-voltage DC bus drop below 200V
Momentary Power Loss 0~2 sec: Inverter can be restarted by speed search
Stall prevention During Acceleration/Deceleration/Constant speed
Output short circuit Provided by electronic circuit
Ground fault Provided by electronic circuit
Other Protection Heat sink fin overheat, current limit
Dimension L*A*P=72 mm* 130 mm* 113 mm
Mounting dimension L*A=62 mm* 115 mm
Installation Direct installation or using DIN rail (Option)



Inverters, inverter E2. Mipro-SyncroFlow Elettroquadri: It becomes popular in the field of plant control systems for the automation and the movement in several productive fields.